vane-type cavity magnetron - traducción al ruso

DEVICE FOR GENERATING MICROWAVES
Magnetron; Radar cavity; Cavity Magnetron; Split-anode magnetron
  • [[ISO 7010]] Warning sign: Non-ionizing radiation
  • Cutaway drawing of a cavity magnetron of 1984.  Part of the righthand magnet and copper anode block is cut away to show the cathode and cavities.  This older magnetron uses two horseshoe shaped [[alnico]] magnets, modern tubes use [[rare-earth magnet]]s.
  • 9.375 GHz 20 kW (peak) magnetron assembly for an early commercial airport radar in 1947.  In addition to the magnetron (right), it contains a TR (transmit/receive) switch tube and the [[superheterodyne]] receiver front end, a 2K25 [[reflex klystron]] tube [[local oscillator]] and a 1N21 [[germanium diode]] mixer. The waveguide aperture (left) would be connected to a waveguide going to the antenna.
  • The electromagnet used in conjunction with Randall and Boot's original magnetron, in the Science Museum, London.
  • The anode block which is part of the cavity magnetron developed by Randall and Boot
  • Sir John Randall]] and [[Harry Boot]]'s original cavity magnetron developed in 1940 at the [[University of Birmingham]], England, now in the [[Science Museum, London]].
  • Split-anode magnetron (c. 1935). ''(left)'' The bare tube, about 11 cm high. ''(right)'' Installed for use between the poles of a strong [[permanent magnet]]

vane-type cavity magnetron      
равнорезонаторный магнетрон
cavity magnetron         

существительное

физика

магнетрон, обеспечивающий большой выход энергии

split-anode magnetron         

общая лексика

магнетрон разрезной

магнетрон с разрезным анодом

радиотехника

магнетрон двухрезной

Definición

magnetron
['magn?tr?n]
¦ noun an electron tube for amplifying or generating microwaves, with the flow of electrons controlled by an external magnetic field.

Wikipedia

Cavity magnetron

The cavity magnetron is a high-power vacuum tube used in early radar systems and currently in microwave ovens and linear particle accelerators. It generates microwaves using the interaction of a stream of electrons with a magnetic field while moving past a series of cavity resonators, which are small, open cavities in a metal block. Electrons pass by the cavities and cause microwaves to oscillate within, similar to the functioning of a whistle producing a tone when excited by an air stream blown past its opening. The resonant frequency of the arrangement is determined by the cavities' physical dimensions. Unlike other vacuum tubes, such as a klystron or a traveling-wave tube (TWT), the magnetron cannot function as an amplifier for increasing the intensity of an applied microwave signal; the magnetron serves solely as an oscillator, generating a microwave signal from direct current electricity supplied to the vacuum tube.

The use of magnetic fields as a means to control the flow of an electrical current was spurred by the invention of the Audion by Lee de Forest in 1906. Albert Hull of General Electric Research Laboratory, USA, began development of magnetrons to avoid de Forest's patents, but these were never completely successful. Other experimenters picked up on Hull's work and a key advance, the use of two cathodes, was introduced by Habann in Germany in 1924. Further research was limited until Okabe's 1929 Japanese paper noting the production of centimeter-wavelength signals, which led to worldwide interest. The development of magnetrons with multiple cathodes was proposed by A. L. Samuel of Bell Telephone Laboratories in 1934, leading to designs by Postumus in 1934 and Hans Hollmann in 1935. Production was taken up by Philips, General Electric Company (GEC), Telefunken and others, limited to perhaps 10 W output. By this time the klystron was producing more power and the magnetron was not widely used, although a 300W device was built by Aleksereff and Malearoff in the USSR in 1936 (published in 1940).

The cavity magnetron was a radical improvement introduced by John Randall and Harry Boot at the University of Birmingham, England in 1940. Their first working example produced hundreds of watts at 10 cm wavelength, an unprecedented achievement. Within weeks, engineers at GEC had improved this to well over a kilowatt, and within months 25 kilowatts, over 100 kW by 1941 and pushing towards a megawatt by 1943. The high power pulses were generated from a device the size of a small book and transmitted from an antenna only centimeters long, reducing the size of practical radar systems by orders of magnitude. New radars appeared for night-fighters, anti-submarine aircraft and even the smallest escort ships, and from that point on the Allies of World War II held a lead in radar that their counterparts in Germany and Japan were never able to close. By the end of the war, practically every Allied radar was based on a magnetron.

The magnetron continued to be used in radar in the post-war period but fell from favour in the 1960s as high-power klystrons and traveling-wave tubes emerged. A key characteristic of the magnetron is that its output signal changes from pulse to pulse, both in frequency and phase. This renders it less suitable for pulse-to-pulse comparisons for performing moving target indication and removing "clutter" from the radar display. The magnetron remains in use in some radar systems, but has become much more common as a low-cost source for microwave ovens. In this form, over one billion magnetrons are in use today.

¿Cómo se dice vane-type cavity magnetron en Ruso? Traducción de &#39vane-type cavity magnetron&#39 a